22 changes: 19 additions & 3 deletions spec/additionalDescription/MetadataTableUpdateProcess.md
Original file line number Diff line number Diff line change
Expand Up @@ -111,6 +111,22 @@ By providing the mappings in the *deviceTypeMapping* profileInstance, the mappin

## Filtering of metadata

The service /v1/provide-device-status-metadata requires a list of device names, for which the metadata shall be returned, to be provided in the requestBody.
Listed device names, for which no data could be found in the metadata table, are ignored.

There are two options for data retrieval. The filter is mandatory and provided in the requestBody:
- **_MountNameList_**: when the service is called, a mount-name list can be handed over as input.
- The metadata table data is filtered for devices found in the list.
- Data for other devices is not returned.
- **_TimestampFilter_**: the 2nd option is a filter on the *last-complete-control-construct-update-time* property.
- It shall return an output list with only a single device record (if found).
- Only devices in *connected* state are to be considered.
- Depending on the provided value, the data shall be filtered for the device with:
- the oldest, not-null timestamp value: this will be used for the quality measurements
- or for the oldest or null timestamp value (if there are multiple devices with null timestamps, take the first one found): this is to be used for the regular cyclic CC updates (slidingWindow process)

## Sorting the metadata table

In order to efficiently allow for filtering on the *last-complete-control-construct-update-time* timestamp values, the devices in the metadata table should be ordered accordingly.
The devices shall be ordered according to the timestamp value, in from-oldest-to-newest order. Starting with those devices where the timestamp is *null* (as those shall be updated with priority).

Ordering updates:
- after successful ControlConstruct retrieval: move device to the end of the table
- in case of failed retrievals (after the configured amount of retries): also move it to the end of the table
Loading