This API is experimental. Since the uni-meter does not have any information about the current charging state of the storage, this feature relies on the storage's default behavior when no electrical meter readings are provided. So if charging shall be prevented, the uni-meter does not provide any electrical meter readings to the storage if electrical energy is feed into the grid. In the case of discharging prevention, it is the opposite. In both cases the storage should fall back to its default behavior, which should result in an inactive storage.

To stop these operation modes again, you can use the switch_on API call as described here.

Prevent charging

Using this API call, you can prevent the storage from charging for a certain time. This might, for instance, be used to prevent charging before 11am to use your storage in a more "grid-friendly" way. The command takes an optional parameter for the duration of the behavior. Afterward, the uni-meter switches automatically back to its normal operation mode:

http://<uni-meter-ip>:<uni-meter-port>/api/no_charge?seconds=3600

Prevent discharging

Using this API call, you can prevent the storage from discharging for a certain time. This might, for instance, be used to prevent discharging while charging your BEV. The command takes an optional parameter for the duration of the behavior. Afterward, the uni-meter switches automatically back to its normal operation mode:

http://<uni-meter-ip>:<uni-meter-port>/api/no_discharge?seconds=3600