Skip to content

Examples

Janaka Ranasinghesagara edited this page Jan 29, 2026 · 12 revisions

Example 1: Monodisperse Distribution (Single Wavelength) –Comparison with an alternative Mie Tool

This example presents a single-wavelength simulation for monodisperse spheres possessing a complex refractive index. The results from the Mie Simulator GUI demonstrate excellent agreement with Scott Prahl's Mie Scattering Calculator; minor discrepancies primarily attributed to rounding.

Simulation parameters:

Sphere Diameter: 1.0microns
Refractive Index of Medium: 1.33
Real Refractive Index of Sphere: 1.5
Imaginary Refractive Index of Sphere: -0.5
Wavelength: 632.8nm
Number Density: 1e8spheres/mm3
Number of Angles: 360 (dtheta = π/360 = 0.5˚)

Mie-Example1

Comparison:

Mie-Example1


Example 2: Polydisperse Distribution (Multi-Wavelength) – Scattering of Intralipid Phantoms

To demonstrate the tool's scientific utility, we characterize Intralipid 20%, a standard tissue phantom used in biomedical optics (DiNinni2011). Intralipid 20% (w/w) corresponds to a volume fraction of 0.227 (Aernouts2013). Following Raju2017, we assumed a mean particle diameter and standard deviation of 0.22 µm and 0.4 µm, respectively.

Simulation parameters:

Poly Disperse Distribution: Log Normal
Mean Diameter: 0.22 microns
Std. Deviation: 0.4 microns
Number of Sph. Sizes: 101
Refractive Index of Medium: 1.33
Real Refractive Index of Sphere: 1.47
Imaginary Refractive Index of Sphere: 0
Wavelength: 600 nm to 1000 nm in 10 nm steps
Volume Fraction: 0.227
Number of Angles: 360 (dtheta = π/360 = 0.5˚)

Mie-Example2

Mie-Example2

Even though these values may deviate from independent scattering approximation, they remain comparable to experimental data (Aernouts2013) and can be exported as text data files for further analysis.

Clone this wiki locally