.clif Test Case
test optimize
set opt_level=none
set preserve_frame_pointers=true
set enable_multi_ret_implicit_sret=true
function %main() -> i32x4 fast {
ss0 = explicit_slot 32
ss1 = explicit_slot 32
const0 = 0x40ad3fb47cb16076c8cb1fdd8189d40f
block0():
v1 = vconst.i32x4 const0
v2 = bxor_not v1, v1
v3 = icmp.i32x4 ne v1, v2
return v3
}
; print: %main()
Result
When opt_level is set to none, it runs correctly.
[x86 ] %main() -> 0xffffffffffffffffffffffffffffffff
[aarch64] %main() -> 0xffffffffffffffffffffffffffffffff
Then set opt_level to speed.
[x86 ] thread 'main' panicked at cranelift/codegen/src/opts.rs:189:5:
unimplemented for > 64 bits
note: run with `RUST_BACKTRACE=1` environment variable to display a backtrace
return code: 101
[aarch64] thread 'main' panicked at cranelift/codegen/src/opts.rs:189:5:
unimplemented for > 64 bits
note: run with `RUST_BACKTRACE=1` environment variable to display a backtrace
return code: 101
The issue likely occurs during optimization of bxor and icmp instructions.
.clifTest CaseResult
When
opt_levelis set to none, it runs correctly.Then set
opt_levelto speed.The issue likely occurs during optimization of
bxorandicmpinstructions.