Skip to content

fix critical warning for Vivado#162

Open
sequencer wants to merge 2 commits intosifive:masterfrom
sequencer:seq_patch1
Open

fix critical warning for Vivado#162
sequencer wants to merge 2 commits intosifive:masterfrom
sequencer:seq_patch1

Conversation

@sequencer
Copy link
Contributor

@sequencer sequencer commented Apr 25, 2021

@sequencer sequencer changed the title add inline blackbox for PowerOnResetFPGAOnly. fix critical warning for Vivado Apr 25, 2021
@erikdanie
Copy link
Collaborator

erikdanie commented Apr 26, 2021

What is the critical warning that is being fixed here?
I want to make sure we are cautious about merging stuff like this, I will want to hand run some tests.

@sequencer
Copy link
Contributor Author

sequencer commented Apr 26, 2021

What is the critical warning that is being fixed here?

I’m still tuning issue here. I’ll illustrate the problem tomorrow.

This avoid:
[Place 30-722] Terminal 'jtag_jtag_XXX' has IOB constraint set to TRUE,
but it is either not connected to a FLOP element or the connected FLOP
element could not be brought into the I/O

[Constraints 18-841] Port jtag_jtag_XXX has IOB constraint. But it
drives multiple flops. Please specify IOB constraint on individual flop.
The IOB constraint on port will be ignored.
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.