29 changes: 25 additions & 4 deletions apps/predbat/predbat.py
Original file line number Diff line number Diff line change
Expand Up @@ -952,6 +952,10 @@ def self_test(self, minutes_now):
self.base.log(f"======= INVERTER CONTROL SELF TEST START - REST={self.rest_api} ========")
self.adjust_battery_target(99)
self.adjust_battery_target(100)
self.adjust_charge_rate(215)
self.adjust_charge_rate(self.battery_rate_max_charge)
self.adjust_discharge_rate(220)
self.adjust_discharge_rate(self.battery_rate_max_discharge)
self.adjust_reserve(100)
self.adjust_reserve(6)
self.adjust_reserve(4)
Expand Down Expand Up @@ -1002,6 +1006,7 @@ def __init__(self, base, id=0, quiet=False):
self.pv_power = 0
self.load_power = 0
self.rest_api = None
self.in_calibration = False

self.inverter_type = self.base.get_arg("inverter_type", "GE", indirect=False)

Expand Down Expand Up @@ -1052,6 +1057,10 @@ def __init__(self, base, id=0, quiet=False):
# XXX: Weird workaround for battery reporting wrong capacity issue
self.base.log("WARN: REST data reports Battery Capacity kWh as {} but nominal indicates {} - using nominal".format(self.soc_max, self.nominal_capacity))
self.soc_max = self.nominal_capacity
soc_force_adjust = self.rest_data["raw"]["invertor"]["soc_force_adjust"]
if soc_force_adjust and soc_force_adjust != "0" and soc_force_adjust != "7":
self.in_calibration = True
self.log("WARN: Inverter is in calibration mode, Predbat will not function correctly and will be disabled")
self.soc_max *= self.base.battery_scaling

# Max battery rate
Expand Down Expand Up @@ -1856,7 +1865,7 @@ def adjust_charge_rate(self, new_rate, notify=True):
else:
entity = self.base.get_entity(self.base.get_arg("charge_rate", indirect=False, index=self.id))
# Write
self.write_and_poll_value("charge_rate", entity, new_rate, fuzzy=(self.battery_rate_max_charge / 25))
self.write_and_poll_value("charge_rate", entity, new_rate, fuzzy=(self.battery_rate_max_charge * MINUTE_WATT / 25))
if self.inv_output_charge_control == "current":
self.set_current_from_power("charge", new_rate)

Expand Down Expand Up @@ -1904,7 +1913,7 @@ def adjust_discharge_rate(self, new_rate, notify=True):
self.rest_setDischargeRate(new_rate)
else:
entity = self.base.get_entity(self.base.get_arg("discharge_rate", indirect=False, index=self.id))
self.write_and_poll_value("discharge_rate", entity, new_rate, fuzzy=(self.battery_rate_max_discharge / 25))
self.write_and_poll_value("discharge_rate", entity, new_rate, fuzzy=(self.battery_rate_max_discharge * MINUTE_WATT / 25))

if self.inv_output_charge_control == "current":
self.set_current_from_power("discharge", new_rate)
Expand Down Expand Up @@ -2649,7 +2658,7 @@ def rest_setChargeRate(self, rate):
# time.sleep(10)
self.rest_data = self.rest_runAll(self.rest_data)
new = self.rest_data["Control"]["Battery_Charge_Rate"]
if abs(new - rate) < (self.battery_rate_max_charge / 25):
if abs(new - rate) < (self.battery_rate_max_charge * MINUTE_WATT / 25):
self.base.log("Inverter {} set charge rate {} via REST successful on retry {}".format(self.id, rate, retry))
return True

Expand All @@ -2669,7 +2678,7 @@ def rest_setDischargeRate(self, rate):
# time.sleep(10)
self.rest_data = self.rest_runAll(self.rest_data)
new = self.rest_data["Control"]["Battery_Discharge_Rate"]
if abs(new - rate) < (self.battery_rate_max_discharge / 25):
if abs(new - rate) < (self.battery_rate_max_discharge * MINUTE_WATT / 25):
self.base.log("Inverter {} set discharge rate {} via REST successful on retry {}".format(self.id, rate, retry))
return True

Expand Down Expand Up @@ -9158,6 +9167,9 @@ def balance_inverters(self):
for id in range(num_inverters):
inverter = Inverter(self, id, quiet=True)
inverter.update_status(minutes_now, quiet=True)
if inverter.in_calibration:
self.log("Inverter {} is in calibration mode, not balancing".format(id))
return
inverters.append(inverter)

out_of_balance = False # Are all the SOC % the same
Expand Down Expand Up @@ -9683,6 +9695,15 @@ def execute_plan(self):
if self.set_read_only:
status = "Read-Only"
continue
# Inverter is in calibration mode
if inverter.in_calibration:
status = "Calibration"
inverter.adjust_charge_rate(inverter.battery_rate_max_charge * MINUTE_WATT)
inverter.adjust_discharge_rate(inverter.battery_rate_max_discharge * MINUTE_WATT)
inverter.adjust_battery_target(100.0)
inverter.adjust_reserve(0)
self.log("Inverter is in calibration mode, not executing plan and enabling charge/discharge at full rate.")
break

resetDischarge = False
if (not self.set_discharge_during_charge) or (not self.car_charging_from_battery):
Expand Down