390 changes: 390 additions & 0 deletions zhaquirks/danfoss/icon2.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,390 @@
"""ZHA quirk for Danfoss Icon2 main controller (model 0x0210).

Uses the QuirkV2 builder API so that Home Assistant automatically creates
entities for all manufacturer-specific attributes — no ZHA Toolkit needed.
Supports 1 to 16 zone endpoints; entities are only created for endpoints
that actually exist on the paired device.

Entities created automatically per zone endpoint (1–16):
binary_sensor output_status – zone valve actively heating (standard)
binary_sensor icon2_pre_heat_status – pre-heat cycle running (diagnostic)
sensor room_status_code – zone error flags (raw bitmap) (diagnostic)
select room_floor_sensor_mode – floor sensor operating mode (config)
select schedule_type_used – regular vs vacation schedule (config)
switch icon2_pre_heat – enable/disable pre-heat (config)

Entities created automatically on endpoint 232 (main controller):
binary_sensor heat_supply_request – pump/boiler relay active (standard)
sensor system_status_code – system error flags (raw bitmap)(diagnostic)
sensor system_status_water – hot/cool water in pipes (diagnostic)
sensor multimaster_role – master/slave role (diagnostic)
select icon_forced_heating_cooling – force heating or cooling mode (config)

Standard entities (climate per zone, floor temp sensor, humidity sensor, battery)
are created automatically by ZHA from the standard clusters without any quirk.

Note on bitmap sensors (system_status_code, room_status_code): ZHA shows the
raw integer. To check an individual error flag in a template sensor, use:
{{ (states('sensor.icon2_system_status_code') | int) | bitwise_and(1) != 0 }}
(bit 0 = missing_expansion_board, bit 1 = missing_radio_module, etc.)
"""

from zigpy.quirks import CustomCluster
from zigpy.quirks.v2 import QuirkBuilder
from zigpy.quirks.v2.homeassistant import EntityPlatform, EntityType
from zigpy.quirks.v2.homeassistant.binary_sensor import BinarySensorDeviceClass
from zigpy.quirks.v2.homeassistant.sensor import SensorStateClass
import zigpy.types as t
from zigpy.zcl.clusters.homeautomation import Diagnostic
from zigpy.zcl.clusters.hvac import Thermostat
from zigpy.zcl.foundation import ZCLAttributeDef

DANFOSS_MANUFACTURER_CODE = 0x1246

# ---------------------------------------------------------------------------
# Enum / bitmap types matching Z2M converter values
# ---------------------------------------------------------------------------


class DanfossOutputStatus(t.enum8):
"""Zone actuator state – is this zone's valve open and heating."""

inactive = 0x00
active = 0x01


class DanfossRoomStatusCode(t.bitmap16):
"""Zone thermostat error flags (multiple bits may be set simultaneously)."""

no_error = 0x0000
missing_rt = 0x0001
rt_touch_error = 0x0002
floor_sensor_short_circuit = 0x0004
floor_sensor_disconnected = 0x0008


class DanfossRoomFloorSensorMode(t.enum8):
"""Floor sensor operating mode."""

comfort = 0x00
floor_only = 0x01
dual_mode = 0x02


class DanfossScheduleTypeUsed(t.enum8):
"""Which schedule is currently active on this zone."""

regular_schedule_selected = 0x00
vacation_schedule_selected = 0x01


class DanfossPreHeat(t.enum8):
"""Preheat feature enabled or disabled."""

disable = 0x00
enable = 0x01


class DanfossPreHeatStatus(t.enum8):
"""Preheat cycle currently running."""

disable = 0x00
enable = 0x01


class DanfossSystemStatusCode(t.bitmap16):
"""Main controller system error/status bitmap."""

no_error = 0x0000
missing_expansion_board = 0x0001
missing_radio_module = 0x0002
missing_command_module = 0x0004
missing_master_rail = 0x0008
missing_slave_rail_no_1 = 0x0010
missing_slave_rail_no_2 = 0x0020
pt1000_input_short_circuit = 0x0040
pt1000_input_open_circuit = 0x0080
error_on_one_or_more_output = 0x0100


class DanfossHeatSupplyRequest(t.enum8):
"""Main controller heat demand – drives the pump/boiler relay output."""

none = 0x00
heat_supply_request = 0x01


class DanfossSystemStatusWater(t.enum8):
"""Water flow direction in the hydronic circuit."""

hot_water_flow_in_pipes = 0x00
cool_water_flow_in_pipes = 0x01


class DanfossMultimasterRole(t.enum8):
"""Role of this controller in a multimaster setup."""

invalid_unused = 0x00
master = 0x01
slave_1 = 0x02
slave_2 = 0x03


class DanfossIconForcedHeatingCooling(t.enum8):
"""Forced heating or cooling override mode."""

force_heating = 0x00
force_cooling = 0x01
none = 0x02


# ---------------------------------------------------------------------------
# Custom Thermostat cluster for zone endpoints (1–16).
# Inherits all standard Thermostat attributes and adds Danfoss zone-specific
# manufacturer attributes. Using a subclass instead of patching the global
# Thermostat class avoids breaking other quirks that also subclass Thermostat.
# ---------------------------------------------------------------------------


class DanfossZoneThermostatCluster(CustomCluster, Thermostat):
"""Thermostat cluster for Danfoss Icon2 zone endpoints."""

class AttributeDefs(Thermostat.AttributeDefs):
"""Attribute definitions including Danfoss zone manufacturer attributes."""

room_status_code: ZCLAttributeDef = ZCLAttributeDef(
id=0x4100,
type=DanfossRoomStatusCode,
access="rp",
manufacturer_code=DANFOSS_MANUFACTURER_CODE,
)
output_status: ZCLAttributeDef = ZCLAttributeDef(
id=0x4110,
type=DanfossOutputStatus,
access="rp",
manufacturer_code=DANFOSS_MANUFACTURER_CODE,
)
room_floor_sensor_mode: ZCLAttributeDef = ZCLAttributeDef(
id=0x4120,
type=DanfossRoomFloorSensorMode,
access="rwp",
manufacturer_code=DANFOSS_MANUFACTURER_CODE,
)
floor_min_setpoint: ZCLAttributeDef = ZCLAttributeDef(
id=0x4121,
type=t.int16s,
access="rwp",
manufacturer_code=DANFOSS_MANUFACTURER_CODE,
)
floor_max_setpoint: ZCLAttributeDef = ZCLAttributeDef(
id=0x4122,
type=t.int16s,
access="rwp",
manufacturer_code=DANFOSS_MANUFACTURER_CODE,
)
schedule_type_used: ZCLAttributeDef = ZCLAttributeDef(
id=0x4130,
type=DanfossScheduleTypeUsed,
access="rwp",
manufacturer_code=DANFOSS_MANUFACTURER_CODE,
)
icon2_pre_heat: ZCLAttributeDef = ZCLAttributeDef(
id=0x4131,
type=DanfossPreHeat,
access="rwp",
manufacturer_code=DANFOSS_MANUFACTURER_CODE,
)
icon2_pre_heat_status: ZCLAttributeDef = ZCLAttributeDef(
id=0x414F,
type=DanfossPreHeatStatus,
access="rp",
manufacturer_code=DANFOSS_MANUFACTURER_CODE,
)


# ---------------------------------------------------------------------------
# Custom Diagnostic cluster for endpoint 232 (main controller).
# heat_supply_request (0x4031) drives the pump/boiler relay output.
# ---------------------------------------------------------------------------


class DanfossMainDiagnosticCluster(CustomCluster, Diagnostic):
"""Diagnostic cluster on endpoint 232 with Danfoss system-level attributes."""

class AttributeDefs(Diagnostic.AttributeDefs):
"""Attribute definitions including Danfoss system-level manufacturer attributes."""

system_status_code: ZCLAttributeDef = ZCLAttributeDef(
id=0x4000,
type=DanfossSystemStatusCode,
access="rp",
manufacturer_code=DANFOSS_MANUFACTURER_CODE,
)
heat_supply_request: ZCLAttributeDef = ZCLAttributeDef(
id=0x4031,
type=DanfossHeatSupplyRequest,
access="rwp",
manufacturer_code=DANFOSS_MANUFACTURER_CODE,
)
system_status_flags: ZCLAttributeDef = ZCLAttributeDef(
id=0x4100,
type=t.bitmap16,
access="rp",
manufacturer_code=DANFOSS_MANUFACTURER_CODE,
)
system_status_water: ZCLAttributeDef = ZCLAttributeDef(
id=0x4200,
type=DanfossSystemStatusWater,
access="rp",
manufacturer_code=DANFOSS_MANUFACTURER_CODE,
)
multimaster_role: ZCLAttributeDef = ZCLAttributeDef(
id=0x4201,
type=DanfossMultimasterRole,
access="rp",
manufacturer_code=DANFOSS_MANUFACTURER_CODE,
)
icon_application: ZCLAttributeDef = ZCLAttributeDef(
id=0x4210,
type=t.uint8_t,
access="rp",
manufacturer_code=DANFOSS_MANUFACTURER_CODE,
)
icon_forced_heating_cooling: ZCLAttributeDef = ZCLAttributeDef(
id=0x4220,
type=DanfossIconForcedHeatingCooling,
access="rwp",
manufacturer_code=DANFOSS_MANUFACTURER_CODE,
)
system_string_4300: ZCLAttributeDef = ZCLAttributeDef(
id=0x4300,
type=t.CharacterString,
access="rwp",
manufacturer_code=DANFOSS_MANUFACTURER_CODE,
)


# ---------------------------------------------------------------------------
# QuirkV2 builder registration
#
# Zone endpoints (1–16): .replaces() swaps in DanfossZoneThermostatCluster so
# that ZHA can discover the manufacturer-specific zone attributes. Entity
# declarations are registered for all 16 possible zone endpoints; ZHA silently
# ignores endpoints that don't exist on the actual device, so a 4-zone unit
# will only get entities for endpoints 1–4.
#
# Endpoint 232 is the main controller. .replaces() is safe here because
# endpoint 232 always exists on the Icon2.
# ---------------------------------------------------------------------------

_builder = QuirkBuilder("Danfoss", "0x0210")

# Zone endpoints 1–16
for _ep in range(1, 17):
_builder = (
_builder.replaces(DanfossZoneThermostatCluster, endpoint_id=_ep)
.binary_sensor(
attribute_name="output_status",
cluster_id=Thermostat.cluster_id,
endpoint_id=_ep,
device_class=BinarySensorDeviceClass.HEAT,
fallback_name=f"Zone {_ep} heating",
)
.binary_sensor(
attribute_name="icon2_pre_heat_status",
cluster_id=Thermostat.cluster_id,
endpoint_id=_ep,
device_class=BinarySensorDeviceClass.HEAT,
fallback_name=f"Zone {_ep} pre-heat active",
entity_type=EntityType.DIAGNOSTIC,
)
.sensor(
attribute_name="room_status_code",
cluster_id=Thermostat.cluster_id,
endpoint_id=_ep,
state_class=SensorStateClass.MEASUREMENT,
translation_key="room_status_code",
fallback_name="Room status",
entity_type=EntityType.DIAGNOSTIC,
)
.enum(
attribute_name="room_floor_sensor_mode",
enum_class=DanfossRoomFloorSensorMode,
cluster_id=Thermostat.cluster_id,
endpoint_id=_ep,
translation_key="room_floor_sensor_mode",
fallback_name="Floor sensor mode",
entity_type=EntityType.CONFIG,
)
.enum(
attribute_name="schedule_type_used",
enum_class=DanfossScheduleTypeUsed,
cluster_id=Thermostat.cluster_id,
endpoint_id=_ep,
translation_key="schedule_type_used",
fallback_name="Schedule",
entity_type=EntityType.CONFIG,
)
.switch(
attribute_name="icon2_pre_heat",
cluster_id=Thermostat.cluster_id,
endpoint_id=_ep,
on_value=DanfossPreHeat.enable,
off_value=DanfossPreHeat.disable,
translation_key="icon2_pre_heat",
fallback_name="Pre-heat",
entity_type=EntityType.CONFIG,
)
)

# Main controller (endpoint 232)
(
_builder.replaces(DanfossMainDiagnosticCluster, endpoint_id=232)
.binary_sensor(
attribute_name="heat_supply_request",
cluster_id=Diagnostic.cluster_id,
endpoint_id=232,
device_class=BinarySensorDeviceClass.RUNNING,
translation_key="heat_supply_request",
fallback_name="Pump running",
)
.sensor(
attribute_name="system_status_code",
cluster_id=Diagnostic.cluster_id,
endpoint_id=232,
translation_key="system_status_code",
fallback_name="System status",
entity_type=EntityType.DIAGNOSTIC,
)
.enum(
attribute_name="system_status_water",
enum_class=DanfossSystemStatusWater,
cluster_id=Diagnostic.cluster_id,
endpoint_id=232,
entity_platform=EntityPlatform.SENSOR,
translation_key="system_status_water",
fallback_name="Water flow mode",
entity_type=EntityType.DIAGNOSTIC,
)
.enum(
attribute_name="multimaster_role",
enum_class=DanfossMultimasterRole,
cluster_id=Diagnostic.cluster_id,
endpoint_id=232,
entity_platform=EntityPlatform.SENSOR,
translation_key="multimaster_role",
fallback_name="Controller role",
entity_type=EntityType.DIAGNOSTIC,
)
.enum(
attribute_name="icon_forced_heating_cooling",
enum_class=DanfossIconForcedHeatingCooling,
cluster_id=Diagnostic.cluster_id,
endpoint_id=232,
translation_key="icon_forced_heating_cooling",
fallback_name="Forced heating/cooling mode",
entity_type=EntityType.CONFIG,
)
.also_applies_to("Danfoss", "0x8020")
.add_to_registry()
)
Loading